ROFU 1500 Series Solenoid

ROFU 1500copy

Old design 1500 Series (1980-2013): Hint if you lose the label there is an easy way to determine the voltage… Remove the cover plate on the housing, Be careful not to lose those tiny screws, you will see you have exposed the coil and the workings of the strike now… if there is no tape over the coil it is -01, yellow tape is -05, blue tape is -08)

  NEW 1500 SERIES  NEW 1500 SERIES BACK 
 
Above are photos of the newly arrived (December 2014) 1500 series solenoids..  
Same ROFU keeper, same ROFU cover plate,  then we redesigned everything else!
The housing, the cam, the anchor, the anchor post, the coil, the coil mounting, and the terminal screw strip.
 
Fail Secure (needs power to unlock)
Voltages options as follows:
 
1500-01G is 3-6 VDC/8-16 VAC Intermittent Duty Only (blue & white tape around the coil)
1500-05G is 12 VAC Intermittent or 12 VDC Continuous Duty (blue tape around the coil)
1500-08G is 24 VAC Intermittent or 24 VDC Continuous Duty (black tape around the coil)
 
This completes the 1501/1505/1507/1508/1509/1512 Series Strikes 
PoE Friendly! 
Voltage Specifications for the ROFU® 1500 Series
Fail Secure Strikes:Int. / Intermittent use: not to exceed 10 seconds
Cont. / Continuous use: for a longer period of 10 seconds to indefinite.
 OHMS LAW: VOLTAGE ÷ RESISTANCE = AMPS 

VOLTAGE

AMPS OHMS VAC INT.     VAC CONT.   VDC INT.     VDC CONT.

SPECIFY

8-16 VAC OR
3-6 VDC
Use Ohms Law
4.2
YES
NO
YES
NO
-01
12 VAC
12 VDC
.194
.240
49
YES
NO
YES
YES
-05
24 VAC OR
24 VDC
.123
.146
164
YES
NO
YES
YES
-08
 
In this March 2016 video you see the ROFU 1500G Series in being cycle tested.
 
In this March 2016 video you see the ROFU 1500G Series in being cycle tested.