STRIKES 1400/3400 SERIES

1400/3400 SOLENOID
1400 STANDARD FEATURES
- Rated for continuous for VDC and intermittent duty (not exceeding 10 seconds) for VAC
- Specify RH solenoids for Models 1401, 1430LH, 1440LH
- Specify LH solenoids for Models 1430RH, 1440RH
- 1400-G Series are centerd (non-handed), compatible for all models except 1430 and 1440


3400 STANDARD FEATURES
Rated for continuous duty, VDC only.
Specify RH solenoids for Models 3401, 3430LH, 3440LH, 3460B/RH and 3470B/RH
Specify LH solenoids for Models 3430RH, 3440RH, 3460B/LH and 3470B/LH




SPECIFICATION 1400 SOLENOID
MODELS DESCRIPTION VOLTAGE CURRENT DRAW OHMS
1400-01G
1400-01R
1400-01L
Solenoid 8-16 VAC, 3-6 VDC 0.33~0.8A
0.75A, Ohm's Law
Ohm's Law
16
5
5
1400-05G
1400-05R
1400-05L
Solenoid 12 VAC/VDC 0.28A
0.194A/0.24A
0.194A/0.24A
41
49
49
1400-08G
1400-08R
1400-08L
Solenoid 24 VAC/VDC 0.16A
0.123A/0.146A
0.123A/0.146A
148
164
164